• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Defence Standards
  • ARMY - GL - U.S. Army Natick Soldier Research, Development & Engineering Center
  • View Item
  •   YSE
  • Defence Standards
  • ARMY - GL - U.S. Army Natick Soldier Research, Development & Engineering Center
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

MIL-PRF-32335

TRICON REFRIGERATED CONTAINER SYSTEM (TRCS)

Organization:
ARMY - GL - U.S. Army Natick Soldier Research, Development & Engineering Center
Year: 2010

Abstract: This performance specification covers the Governments TriCon Refrigerated Container System (TRCS). The TRCS is made up of two principle components:
A Triple Container (TriCon) sized (8-foot wide by 6-foot 5 and half inches long by 8 foot high), International Organization of Standardization (ISO) compliant, insulated container (referred to as "container") and an integrated refrigeration/freezing/heating unit (referred to as "RU") per:
• Type I - electrically powered RU with full width double door container
• Type II - diesel/electric powered RU with full width double door container
•Type III - electrically powered RU with a single man door, recessed operating handle container
For Type I and II, the TRCS doors will be located on the side of the container (6.5 foot dimension) to allow full access inside when the container is coupled. The RU will be located on the side opposite to the door. For type III, a single man door with self closing pull style door handle is required.
When the container and the RU are combined, this will be referred to as the "system". The container will include certain added features called out in this performance specification. (i.e. interior tie downs, horizontal A or E track, air strip curtains, etc...).Intended Use: The TRCS system is intended for use in the transportation of equipment and storage of non-perishables and perishables items (food) and other temperature sensitive commodities (human remains) requiring controlled temperature. These containers are based on commercial designs, manufactured using commercial processes, and are modified for military unique requirements for operation in an extreme environment, under conditions typically found on the battlefield.
URI: http://mapnamagz.yabesh.ir/std;query=authoF23793FD08/handle/yse/67512
Subject: Electric driven refrigeration unit
Collections :
  • ARMY - GL - U.S. Army Natick Soldier Research, Development & Engineering Center
  • Download PDF : (822.9Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    MIL-PRF-32335

Show full item record

contributor authorARMY - GL - U.S. Army Natick Soldier Research, Development & Engineering Center
date accessioned2017-09-04T16:04:10Z
date available2017-09-04T16:04:10Z
date copyright07/14/2010
date issued2010
identifier otherRSQIUCAAAAAAAAAA.pdf
identifier urihttp://mapnamagz.yabesh.ir/std;query=authoF23793FD08/handle/yse/67512
description abstractThis performance specification covers the Governments TriCon Refrigerated Container System (TRCS). The TRCS is made up of two principle components:
A Triple Container (TriCon) sized (8-foot wide by 6-foot 5 and half inches long by 8 foot high), International Organization of Standardization (ISO) compliant, insulated container (referred to as "container") and an integrated refrigeration/freezing/heating unit (referred to as "RU") per:
• Type I - electrically powered RU with full width double door container
• Type II - diesel/electric powered RU with full width double door container
•Type III - electrically powered RU with a single man door, recessed operating handle container
For Type I and II, the TRCS doors will be located on the side of the container (6.5 foot dimension) to allow full access inside when the container is coupled. The RU will be located on the side opposite to the door. For type III, a single man door with self closing pull style door handle is required.
When the container and the RU are combined, this will be referred to as the "system". The container will include certain added features called out in this performance specification. (i.e. interior tie downs, horizontal A or E track, air strip curtains, etc...).Intended Use: The TRCS system is intended for use in the transportation of equipment and storage of non-perishables and perishables items (food) and other temperature sensitive commodities (human remains) requiring controlled temperature. These containers are based on commercial designs, manufactured using commercial processes, and are modified for military unique requirements for operation in an extreme environment, under conditions typically found on the battlefield.
languageEnglish
titleMIL-PRF-32335num
titleTRICON REFRIGERATED CONTAINER SYSTEM (TRCS)en
typestandard
page66
statusActive
treeARMY - GL - U.S. Army Natick Soldier Research, Development & Engineering Center:;2010
contenttypefulltext
subject keywordsElectric driven refrigeration unit
subject keywordsISO container
subject keywordsRefrigerator
subject keywordsfield
subject keywordsStorage
subject keywordsfood
subject keywordsTransportation
subject keywordsfood
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian