MIL-R-23098A
REGULATORS, LINE VOLTAGE, SINGLE PHASE, 400 HERTZ A.C. NAVAL SHIPBOARD
Organization:
NAVY - SH - Naval Sea Systems Command (Ship Systems)
Year: 1970
Abstract: This specification covers general requirements for single phase, 400 Hertz (Hz) alternating current (a.c.) line voltage requlators intended for shipboard application. The single-phase regulators shall operate in a three-phase bank when connected in a fourwire wye circuit with or without a grounded neutral, or in a delta circuit.
The continuous load capacity of the three-phase bank shall be limited by the maximum line current rating of the single-phase equipment. Equipments shall be of the following ratings as specified (see 6.1):
The continuous load capacity of the three-phase bank shall be limited by the maximum line current rating of the single-phase equipment. Equipments shall be of the following ratings as specified (see 6.1):
115 volt system - Equipments are rated at 115 volts (V) root-mean-square (RMS) and the following maximum continuous output line currents: 75 amperes RMS 150 amperes RMS 225 amperes RMS 440 volt system - Equipments are rated at 440V RMS and the following maximum con- tinuous output line currents: 20 amperes RMS 40 amperes RMS
Collections
:
Show full item record
| contributor author | NAVY - SH - Naval Sea Systems Command (Ship Systems) | |
| date accessioned | 2017-09-04T17:57:38Z | |
| date available | 2017-09-04T17:57:38Z | |
| date copyright | 25902 | |
| date issued | 1970 | |
| identifier other | FPKLDAAAAAAAAAAA.pdf | |
| identifier uri | http://mapnamagz.yabesh.ir/std;query=autho1826AF67FCdardstandardsfen/handle/yse/180763 | |
| description abstract | This specification covers general requirements for single phase, 400 Hertz (Hz) alternating current (a.c.) line voltage requlators intended for shipboard application. The single-phase regulators shall operate in a three-phase bank when connected in a fourwire wye circuit with or without a grounded neutral, or in a delta circuit. The continuous load capacity of the three-phase bank shall be limited by the maximum line current rating of the single-phase equipment. Equipments shall be of the following ratings as specified (see 6.1): 115 volt system - Equipments are rated at 115 volts (V) root-mean-square (RMS) and the following maximum continuous output line currents: 75 amperes RMS 150 amperes RMS 225 amperes RMS 440 volt system - Equipments are rated at 440V RMS and the following maximum con- tinuous output line currents: 20 amperes RMS 40 amperes RMS | |
| language | English | |
| title | MIL-R-23098A | num |
| title | REGULATORS, LINE VOLTAGE, SINGLE PHASE, 400 HERTZ A.C. NAVAL SHIPBOARD | en |
| type | standard | |
| page | 30 | |
| status | Active | |
| tree | NAVY - SH - Naval Sea Systems Command (Ship Systems):;1970 | |
| contenttype | fulltext |