description abstractThis specification covers general requirements for single phase, 400 Hertz (Hz) alternating current (a.c.) line voltage requlators intended for shipboard application. The single-phase regulators shall operate in a three-phase bank when connected in a fourwire wye circuit with or without a grounded neutral, or in a delta circuit.
The continuous load capacity of the three-phase bank shall be limited by the maximum line current rating of the single-phase equipment. Equipments shall be of the following ratings as specified (see 6.1):
          115 volt system - Equipments are rated at 115 volts (V) root-mean-square (RMS) and                              the following maximum continuous output line currents:                                               75 amperes RMS                                              150 amperes RMS                                              225 amperes RMS            440 volt system - Equipments are rated at 440V RMS and the following maximum con-                              tinuous output line currents:                                              20 amperes RMS                                              40 amperes RMS


languageEnglish
titleMIL-R-23098Anum
titleREGULATORS, LINE VOLTAGE, SINGLE PHASE, 400 HERTZ A.C. NAVAL SHIPBOARDen
typestandard
page30
statusActive
treeNAVY - SH - Naval Sea Systems Command (Ship Systems):;1970
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record