CSA CAN/CSA-C391-15
Testing of three-phase synchronous machines during refurbishment - First Edition; Update No. 1: September 2015
Organization:
CSA - CSA Group
Year: 2015
Abstract: This Standard covers three-phase, alternating current, salient pole synchronous machines 150 kW and up, 200 through 13,800 volts, 60 and 50 Hertz and will assist in verifying the machine efficiency has been maintained.
Note: This Standard can be useful and applied with discretion to products outside the scope of this Standard.
Large 2-pole and 4-pole solid cylindrical rotor machines, typically used as generators for utility and large industrial applications, are excluded from this Standard.
Note: See Annex E for information on generators
In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
Note: This Standard can be useful and applied with discretion to products outside the scope of this Standard.
Large 2-pole and 4-pole solid cylindrical rotor machines, typically used as generators for utility and large industrial applications, are excluded from this Standard.
Note: See Annex E for information on generators
In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
Collections
:
-
Statistics
CSA CAN/CSA-C391-15
Show full item record
| contributor author | CSA - CSA Group | |
| date accessioned | 2017-09-04T18:29:28Z | |
| date available | 2017-09-04T18:29:28Z | |
| date copyright | 2015.01.01 | |
| date issued | 2015 | |
| identifier other | ITOAMFAAAAAAAAAA.pdf | |
| identifier uri | http://mapnamagz.yabesh.ir/std;query=authoF23793FDFCDCAC4/handle/yse/211686 | |
| description abstract | This Standard covers three-phase, alternating current, salient pole synchronous machines 150 kW and up, 200 through 13,800 volts, 60 and 50 Hertz and will assist in verifying the machine efficiency has been maintained. Note: This Standard can be useful and applied with discretion to products outside the scope of this Standard. Large 2-pole and 4-pole solid cylindrical rotor machines, typically used as generators for utility and large industrial applications, are excluded from this Standard. Note: See Annex E for information on generators In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application. | |
| language | English | |
| title | CSA CAN/CSA-C391-15 | num |
| title | Testing of three-phase synchronous machines during refurbishment - First Edition; Update No. 1: September 2015 | en |
| type | standard | |
| page | 54 | |
| status | Active | |
| tree | CSA - CSA Group:;2015 | |
| contenttype | fulltext |

درباره ما