CSA CAN/CSA-Z276-15

Liquefied natural gas (LNG) - Production, storage, and handling - Tenth Edition; Update No.1: January 2016

Organization:
CSA - CSA Group
Year: 2015

Abstract: This Standard applies to the
a) design;
b) location;
c) construction;
d) operation; and
e) maintenance of facilities for the liquefaction of natural gas and facilities for the storage, vaporization, transfer, handling, and truck transport of LNG. It also contains requirements for the training of personnel.
For facilities that load or unload LNG from a marine vessel, this Standard contains requirements for the interconnecting piping between the loading/unloading arm flange and the storage tank(s), and other piping and appurtenances on the pier or jetty itself. 
This Standard applies to all containers for the storage of LNG, including those with insulation systems applying a vacuum. 
This Standard does not apply to frozen ground containers. 
This Standard includes non-mandatory guidelines for
a) small LNG facilities (see the definition of “small facility” in Clause 3 and see Annex B); and
b) LNG vehicle fuelling stations employed for fleet and public LNG vehicle fuel dispensing operations (see the definition of "fuelling station” in Clause D.2 and see Annex D). 
This Standard does not apply to the following:
a) the transportation of refrigerants by any means;
b) the transportation of LNG by railcar or marine vessel;
c) the transportation of LNG or regasified LNG by pipeline beyond the facility boundary, except as specified in Clause 1.2; and
d) facilities designed to allow the use of LNG as a fuel for railroad locomotives, or marine vessels.
All references to pressure throughout this Standard refer to gauge pressures unless otherwise specified.
All pipe sizes refer to nominal pipe sizes (NPS).
The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 
In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
URI: http://mapnamagz.yabesh.ir/std;query=authoF23793FDFCDCAC4/handle/yse/199466
Collections :
  • CSA - CSA Group
  • Download PDF : (3.015Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    CSA CAN/CSA-Z276-15

Show full item record

contributor authorCSA - CSA Group
date accessioned2017-09-04T18:16:34Z
date available2017-09-04T18:16:34Z
date copyright2015.01.01
date issued2015
identifier otherHNDIOFAAAAAAAAAA.pdf
identifier urihttp://mapnamagz.yabesh.ir/std;query=authoF23793FDFCDCAC4/handle/yse/199466
description abstractThis Standard applies to the
a) design;
b) location;
c) construction;
d) operation; and
e) maintenance of facilities for the liquefaction of natural gas and facilities for the storage, vaporization, transfer, handling, and truck transport of LNG. It also contains requirements for the training of personnel.
For facilities that load or unload LNG from a marine vessel, this Standard contains requirements for the interconnecting piping between the loading/unloading arm flange and the storage tank(s), and other piping and appurtenances on the pier or jetty itself. 
This Standard applies to all containers for the storage of LNG, including those with insulation systems applying a vacuum. 
This Standard does not apply to frozen ground containers. 
This Standard includes non-mandatory guidelines for
a) small LNG facilities (see the definition of “small facility” in Clause 3 and see Annex B); and
b) LNG vehicle fuelling stations employed for fleet and public LNG vehicle fuel dispensing operations (see the definition of "fuelling station” in Clause D.2 and see Annex D). 
This Standard does not apply to the following:
a) the transportation of refrigerants by any means;
b) the transportation of LNG by railcar or marine vessel;
c) the transportation of LNG or regasified LNG by pipeline beyond the facility boundary, except as specified in Clause 1.2; and
d) facilities designed to allow the use of LNG as a fuel for railroad locomotives, or marine vessels.
All references to pressure throughout this Standard refer to gauge pressures unless otherwise specified.
All pipe sizes refer to nominal pipe sizes (NPS).
The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 
In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
languageEnglish
titleCSA CAN/CSA-Z276-15num
titleLiquefied natural gas (LNG) - Production, storage, and handling - Tenth Edition; Update No.1: January 2016en
typestandard
page152
statusActive
treeCSA - CSA Group:;2015
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian