• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • CSA - CSA Group
  • View Item
  •   YSE
  • Industrial Standards
  • CSA - CSA Group
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

CSA CAN/CSA-ISO/IEC TR 18047-6:13

Information technology - Radio frequency identification device conformance test methods - Part 6: Test methods for air interface communications at 860 MHz to 960 MHz

Organization:
CSA - CSA Group
Year: 2013

Abstract: This part of ISO/IEC TR 18047 defines test methods for determining the conformance of radio frequency identification (RFID) devices (tags and interrogators) for item management with the specifications given in ISO/IEC 18000-6, but does not apply to the testing of conformity with regulatory or similar requirements.
The test methods require only that the mandatory functions, and any optional functions which are implemented, be verified. This can, in appropriate circumstances, be supplemented by further, applicationspecific functionality criteria that are not available in the general case.
The interrogator and tag conformance parameters in this part of ISO/IEC TR 18047 are the following:
• type-specific conformance parameters including nominal values and tolerances;
• parameters that apply directly affecting system functionality and inter-operability.
The following are not included in this part of ISO/IEC TR 18047:
• parameters that are already included in regulatory test requirements;
• high-level data encoding conformance test parameters (these are specified in ISO/IEC 15962).
Unless otherwise specified, the tests in this part of ISO/IEC TR 18047 are to be applied exclusively to RFID tags and interrogators defined in ISO/IEC 18000-6.
Clause 5 describes all necessary conformance tests for ISO/IEC 18000-6 Type A.
Clause 6 describes all necessary conformance tests for ISO/IEC 18000-6 Type B.
Clause 7 describes all necessary conformance tests for ISO/IEC 18000-6 Type C.
Clause 8 describes all necessary conformance tests for ISO/IEC 18000-6 Type D.
Clause 9 describes all necessary conformance tests for ISO/IEC 18000-6 Type C Battery Assisted Passive (BAP), whereas optional features will only be tested when supported.
Clause 10 describes all necessary conformance tests for ISO/IEC 18000-6 Type C Sensor support, whereas optional features will only be tested when supported.
URI: http://mapnamagz.yabesh.ir/std;query=authoF23793FDFCDCAC4/handle/yse/197810
Collections :
  • CSA - CSA Group
  • Download PDF : (1.765Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    CSA CAN/CSA-ISO/IEC TR 18047-6:13

Show full item record

contributor authorCSA - CSA Group
date accessioned2017-09-04T18:14:51Z
date available2017-09-04T18:14:51Z
date copyright2013.01.01
date issued2013
identifier otherHISPBFAAAAAAAAAA.pdf
identifier urihttp://mapnamagz.yabesh.ir/std;query=authoF23793FDFCDCAC4/handle/yse/197810
description abstractThis part of ISO/IEC TR 18047 defines test methods for determining the conformance of radio frequency identification (RFID) devices (tags and interrogators) for item management with the specifications given in ISO/IEC 18000-6, but does not apply to the testing of conformity with regulatory or similar requirements.
The test methods require only that the mandatory functions, and any optional functions which are implemented, be verified. This can, in appropriate circumstances, be supplemented by further, applicationspecific functionality criteria that are not available in the general case.
The interrogator and tag conformance parameters in this part of ISO/IEC TR 18047 are the following:
• type-specific conformance parameters including nominal values and tolerances;
• parameters that apply directly affecting system functionality and inter-operability.
The following are not included in this part of ISO/IEC TR 18047:
• parameters that are already included in regulatory test requirements;
• high-level data encoding conformance test parameters (these are specified in ISO/IEC 15962).
Unless otherwise specified, the tests in this part of ISO/IEC TR 18047 are to be applied exclusively to RFID tags and interrogators defined in ISO/IEC 18000-6.
Clause 5 describes all necessary conformance tests for ISO/IEC 18000-6 Type A.
Clause 6 describes all necessary conformance tests for ISO/IEC 18000-6 Type B.
Clause 7 describes all necessary conformance tests for ISO/IEC 18000-6 Type C.
Clause 8 describes all necessary conformance tests for ISO/IEC 18000-6 Type D.
Clause 9 describes all necessary conformance tests for ISO/IEC 18000-6 Type C Battery Assisted Passive (BAP), whereas optional features will only be tested when supported.
Clause 10 describes all necessary conformance tests for ISO/IEC 18000-6 Type C Sensor support, whereas optional features will only be tested when supported.
languageEnglish
titleCSA CAN/CSA-ISO/IEC TR 18047-6:13num
titleInformation technology - Radio frequency identification device conformance test methods - Part 6: Test methods for air interface communications at 860 MHz to 960 MHzen
typestandard
page90
statusActive
treeCSA - CSA Group:;2013
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian