CSA C22.2 NO. 210-11

Appliance wiring material products - Third Edition

Organization:
CSA - CSA Group
Year: 2011

Abstract: This Standard applies to single- or multiple-conductor, round, flat, or coiled appliance wiring material products classified as follows:
(a) Class I — internal wiring of equipment (single- or multiple-conductor constructions with or without an insulating covering, covering or jacket):
(i) Group A — not subject to mechanical abuse; and
(ii) Group B — potentially subject to mechanical abuse;
(b) Class II — external/interconnecting wires (single- or multiple-conductor constructions with a jacket):
(i) Group A — not subject to mechanical abuse; and
(ii) Group B — potentially subject to mechanical abuse.
Notes:
(1) As there is a great variety of applications for appliance wiring material products, the use of such a product should be evaluated with the design and construction of the end-use application in mind and should not be judged solely by the requirements of this Standard.
(2) Class I and II products are Group A, B, or both.
(3) Group markings (A, B, or both) relate to tests performed on the individual insulated conductors. Group marking that includes both A and B means all insulated conductors pass Group B tests.
This Standard also applies to appliance wiring material products that have a jacket or overall insulating covering and are used to connect or interconnect data processing and similar systems in accordance with the Canadian Electrical Code, Part I.
In CSA standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
URI: http://mapnamagz.yabesh.ir/std;query=authoF23793FDFCDCAC4/handle/yse/196525
Collections :
  • CSA - CSA Group
  • Download PDF : (706.2Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    CSA C22.2 NO. 210-11

Show full item record

contributor authorCSA - CSA Group
date accessioned2017-09-04T18:13:33Z
date available2017-09-04T18:13:33Z
date copyright2011.10.01
date issued2011
identifier otherHFIEOEAAAAAAAAAA.pdf
identifier urihttp://mapnamagz.yabesh.ir/std;query=authoF23793FDFCDCAC4/handle/yse/196525
description abstractThis Standard applies to single- or multiple-conductor, round, flat, or coiled appliance wiring material products classified as follows:
(a) Class I — internal wiring of equipment (single- or multiple-conductor constructions with or without an insulating covering, covering or jacket):
(i) Group A — not subject to mechanical abuse; and
(ii) Group B — potentially subject to mechanical abuse;
(b) Class II — external/interconnecting wires (single- or multiple-conductor constructions with a jacket):
(i) Group A — not subject to mechanical abuse; and
(ii) Group B — potentially subject to mechanical abuse.
Notes:
(1) As there is a great variety of applications for appliance wiring material products, the use of such a product should be evaluated with the design and construction of the end-use application in mind and should not be judged solely by the requirements of this Standard.
(2) Class I and II products are Group A, B, or both.
(3) Group markings (A, B, or both) relate to tests performed on the individual insulated conductors. Group marking that includes both A and B means all insulated conductors pass Group B tests.
This Standard also applies to appliance wiring material products that have a jacket or overall insulating covering and are used to connect or interconnect data processing and similar systems in accordance with the Canadian Electrical Code, Part I.
In CSA standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
languageEnglish
titleCSA C22.2 NO. 210-11num
titleAppliance wiring material products - Third Editionen
typestandard
page62
statusActive
treeCSA - CSA Group:;2011
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian