• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • CSA - CSA Group
  • View Item
  •   YSE
  • Industrial Standards
  • CSA - CSA Group
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

CSA Z314.1-09

Ethylene oxide sterilizers for health care facilities - Fifth Edition

Organization:
CSA - CSA Group
Year: 2013

Abstract: This Standard applies to ethylene oxide sterilizers that have automatic controls and are intended for general-purpose use in health care facilities.
Notes:
(1) The term "health care facilities" includes, but is not limited to, hospitals, nursing homes, extended-care facilities, clinics, medical and dental offices, and health units in industry.
(2) This Standard is intended for manufacturers of ethylene oxide sterilizers. Tests involving modifications to the sterilizer controls or safety features can present hazards to those who do not possess specialized testing equipment and the expertise to conduct the tests.
This Standard specifies minimum construction, performance, testing, and labelling requirements to ensure that
(a) the environment in the sterilizing chamber is effective in sterilizing products; and
(b) personnel using the equipment are protected from hazards associated with ethylene oxide.
This Standard does not provide requirements for the following:
(a) pre- or post-sterilization procedures;
(b) machine operators;
(c) venting of waste gases used in the sterilization process; and
(d) tests to indicate the probability of product sterility.
In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
URI: http://mapnamagz.yabesh.ir/std;query=authoF23793FDFCDCAC4/handle/yse/195287
Collections :
  • CSA - CSA Group
  • Download PDF : (1.073Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    CSA Z314.1-09

Show full item record

contributor authorCSA - CSA Group
date accessioned2017-09-04T18:12:15Z
date available2017-09-04T18:12:15Z
date copyright2009.01.01 (R 2013)
date issued2013
identifier otherHCBQHFAAAAAAAAAA.pdf
identifier urihttp://mapnamagz.yabesh.ir/std;query=authoF23793FDFCDCAC4/handle/yse/195287
description abstractThis Standard applies to ethylene oxide sterilizers that have automatic controls and are intended for general-purpose use in health care facilities.
Notes:
(1) The term "health care facilities" includes, but is not limited to, hospitals, nursing homes, extended-care facilities, clinics, medical and dental offices, and health units in industry.
(2) This Standard is intended for manufacturers of ethylene oxide sterilizers. Tests involving modifications to the sterilizer controls or safety features can present hazards to those who do not possess specialized testing equipment and the expertise to conduct the tests.
This Standard specifies minimum construction, performance, testing, and labelling requirements to ensure that
(a) the environment in the sterilizing chamber is effective in sterilizing products; and
(b) personnel using the equipment are protected from hazards associated with ethylene oxide.
This Standard does not provide requirements for the following:
(a) pre- or post-sterilization procedures;
(b) machine operators;
(c) venting of waste gases used in the sterilization process; and
(d) tests to indicate the probability of product sterility.
In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
languageEnglish
titleCSA Z314.1-09num
titleEthylene oxide sterilizers for health care facilities - Fifth Editionen
typestandard
page37
statusActive
treeCSA - CSA Group:;2013
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian