Abstract: This standard is applicable to custody transfer applications for liquid hydrocarbons. Topics covered are:
a. Applicable API standards used in the operation of Coriolis meters.
b. Proving and verification using both mass- and volumebased methods.
c. Installation.
d. Operation.
e. Maintenance.
The mass- and volume-based calculation procedures for proving and quantity determination are included in Appendix E.
Although the Coriolis meter is capable of simultaneously determining density, this document does not address its use as a stand-alone densitometer. See API MPMS Chapter 14.6 for this type of application. The measured density from the Coriolis meter is used to convert mass to volume.
a. Applicable API standards used in the operation of Coriolis meters.
b. Proving and verification using both mass- and volumebased methods.
c. Installation.
d. Operation.
e. Maintenance.
The mass- and volume-based calculation procedures for proving and quantity determination are included in Appendix E.
Although the Coriolis meter is capable of simultaneously determining density, this document does not address its use as a stand-alone densitometer. See API MPMS Chapter 14.6 for this type of application. The measured density from the Coriolis meter is used to convert mass to volume.
Collections
:
Show full item record
| contributor author | API - American Petroleum Institute | |
| date accessioned | 2017-09-04T18:10:08Z | |
| date available | 2017-09-04T18:10:08Z | |
| date copyright | 2002.10.01 (R 2013) | |
| date issued | 2013 | |
| identifier other | GWPPHFAAAAAAAAAA.pdf | |
| identifier uri | http://mapnamagz.yabesh.ir/std;query=authoF23793FD081DAC4/handle/yse/193192 | |
| description abstract | This standard is applicable to custody transfer applications for liquid hydrocarbons. Topics covered are: a. Applicable API standards used in the operation of Coriolis meters. b. Proving and verification using both mass- and volumebased methods. c. Installation. d. Operation. e. Maintenance. The mass- and volume-based calculation procedures for proving and quantity determination are included in Appendix E. Although the Coriolis meter is capable of simultaneously determining density, this document does not address its use as a stand-alone densitometer. See API MPMS Chapter 14.6 for this type of application. The measured density from the Coriolis meter is used to convert mass to volume. | |
| language | English | |
| title | API MPMS 5.6 | num |
| title | Manual of Petroleum Measurement Standards Chapter 5-Metering Section 6-Measurement of Liquid Hydrocarbons by Coriolis Meters - FIRST EDITION | en |
| type | standard | |
| page | 54 | |
| status | Active | |
| tree | API - American Petroleum Institute:;2013 | |
| contenttype | fulltext |