• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • View Item
  •   YSE
  • Industrial Standards
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

ASHRAE OR-16-C055

Off-Normal Solar-Optical Performance of Pleated Drapery: Simulation versus Measurement

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2016

Abstract: In recent years, significant advances have been made in modeling fenestration with shading attachments. Most shading devices have great potential for reducing both peak building cooling load and annual energy consumption through the control of solar gains, and the ability to quantify their impact is important. As part of an ASHRAE sponsored research project, several new models were developed for various types of shading devices. One of the most complex of these was the pleated drapery model. This model uses off-normal solar-optical fabric properties to predict the off-normal solar-optical properties of the pleated drapery. In doing so, the model assumes that the system could be represented as a series of uniformly arranged rectangular pleats. The work presented here aims to validate model performance. A Broad-Area Illumination Integrating Sphere (BAI-IS) was used to perform solar transmittance measurements on pleated drape samples. The BAI-IS is capable of measuring optical properties of thick and non-uniform samples. Five pleated drape samples composed of fabrics with different transmittance and reflectance were used in measurements. Results were compared to the model output for different incidence angles. Predicted transmittances were generally within ±0.05 of measured values although there could be an overprediction as much as +0.11 for normal incidence test cases of high transmittance test samples. This discrepancy can be attributed to the geometric difference between the model and the test samples.
URI: http://mapnamagz.yabesh.ir/std;query=authoF23793FD08/handle/yse/232227
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (570.3Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE OR-16-C055

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T18:50:47Z
date available2017-09-04T18:50:47Z
date copyright2016.01.01
date issued2016
identifier otherANXPOFAAAAAAAAAA.pdf
identifier urihttp://mapnamagz.yabesh.ir/std;query=authoF23793FD08/handle/yse/232227
description abstractIn recent years, significant advances have been made in modeling fenestration with shading attachments. Most shading devices have great potential for reducing both peak building cooling load and annual energy consumption through the control of solar gains, and the ability to quantify their impact is important. As part of an ASHRAE sponsored research project, several new models were developed for various types of shading devices. One of the most complex of these was the pleated drapery model. This model uses off-normal solar-optical fabric properties to predict the off-normal solar-optical properties of the pleated drapery. In doing so, the model assumes that the system could be represented as a series of uniformly arranged rectangular pleats. The work presented here aims to validate model performance. A Broad-Area Illumination Integrating Sphere (BAI-IS) was used to perform solar transmittance measurements on pleated drape samples. The BAI-IS is capable of measuring optical properties of thick and non-uniform samples. Five pleated drape samples composed of fabrics with different transmittance and reflectance were used in measurements. Results were compared to the model output for different incidence angles. Predicted transmittances were generally within ±0.05 of measured values although there could be an overprediction as much as +0.11 for normal incidence test cases of high transmittance test samples. This discrepancy can be attributed to the geometric difference between the model and the test samples.
languageEnglish
titleASHRAE OR-16-C055num
titleOff-Normal Solar-Optical Performance of Pleated Drapery: Simulation versus Measurementen
typestandard
page8
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2016
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian