API MPMS 2.2D
Manual of Petroleum Measurement Standards Chapter 2 - Tank Calibration Section 2D - Calibration of Upright Cylindrical Tanks Using the Internal Electro-optical Distance-ranging Method - First Edition
Organization:
API - American Petroleum Institute
Year: 2009
Abstract: This part speciÞes a method for the calibration of upright cylindrical tanks having diameters greater than 5 m by means of internal measurements using an electro-optical distance-ranging instrument, and for the subsequent compilation of tank capacity tables. This method is known as the internal electro-optical distance-ranging (EODR) method.
This part of Chapter 2 is not applicable to the calibration of abnormally deformed (e.g. dented) tanks or of noncircular tanks.
This part of Chapter 2 is applicable to tanks tilted by < or = 3 % from the vertical, provided a correction is applied for the measured tilt as described in Chapter 2.2A.
This part of Chapter 2 is applicable to tanks with coneup or cone-down bottoms, as well as to tanks with flat bottoms.
This part of Chapter 2 is not applicable to the calibration of abnormally deformed (e.g. dented) tanks or of noncircular tanks.
This part of Chapter 2 is applicable to tanks tilted by < or = 3 % from the vertical, provided a correction is applied for the measured tilt as described in Chapter 2.2A.
This part of Chapter 2 is applicable to tanks with coneup or cone-down bottoms, as well as to tanks with flat bottoms.
Collections
:
Show full item record
| contributor author | API - American Petroleum Institute | |
| date accessioned | 2017-09-04T18:07:16Z | |
| date available | 2017-09-04T18:07:16Z | |
| date copyright | 2003.08.01 (R 2009) | |
| date issued | 2009 | |
| identifier other | GOIOLCAAAAAAAAAA.pdf | |
| identifier uri | http://mapnamagz.yabesh.ir/std;query=authoF23793FD08/handle/yse/190146 | |
| description abstract | This part speciÞes a method for the calibration of upright cylindrical tanks having diameters greater than 5 m by means of internal measurements using an electro-optical distance-ranging instrument, and for the subsequent compilation of tank capacity tables. This method is known as the internal electro-optical distance-ranging (EODR) method. This part of Chapter 2 is not applicable to the calibration of abnormally deformed (e.g. dented) tanks or of noncircular tanks. This part of Chapter 2 is applicable to tanks tilted by < or = 3 % from the vertical, provided a correction is applied for the measured tilt as described in Chapter 2.2A. This part of Chapter 2 is applicable to tanks with coneup or cone-down bottoms, as well as to tanks with flat bottoms. | |
| language | English | |
| title | API MPMS 2.2D | num |
| title | Manual of Petroleum Measurement Standards Chapter 2 - Tank Calibration Section 2D - Calibration of Upright Cylindrical Tanks Using the Internal Electro-optical Distance-ranging Method - First Edition | en |
| type | standard | |
| page | 24 | |
| status | Active | |
| tree | API - American Petroleum Institute:;2009 | |
| contenttype | fulltext |

درباره ما