ECA TEP 167
Measurement of X-Radiation from Receiving Tubes, Recommended Practice fo
| contributor author | ECIA - Electronic Components Industry Association | |
| date accessioned | 2017-09-04T15:13:47Z | |
| date available | 2017-09-04T15:13:47Z | |
| date copyright | 01/01/1970 (R 1981) | |
| date issued | 1981 | |
| identifier other | MBGMCAAAAAAAAAAA.pdf | |
| identifier uri | http://mapnamagz.yabesh.ir/std;query=authoF23793FD08/handle/yse/12488 | |
| description abstract | This test method applies to the measurement of x-radiation emitted from high voltage rectifiers and shunt regulators. Purpose To obtain the soft x-radiation characteristics of high voltage receiving tubes in order to determine the levels emitted by the tubes when they are operated at high voltages without shielding. | |
| language | English | |
| title | ECA TEP 167 | num |
| title | Measurement of X-Radiation from Receiving Tubes, Recommended Practice fo | en |
| type | standard | |
| page | 6 | |
| status | Active | |
| tree | ECIA - Electronic Components Industry Association:;1981 | |
| contenttype | fulltext |