CSA CAN/CSA-C22.2 NO. 85-M89
Rigid PVC Boxes and Fittings - Second Edition; General Instruction No. 1: September 1989; General Instruction No. 2: May 1990; Update No. 3: February 2006; Update No. 4: June 2011 and Update No. 5: January 2012
Organization:
CSA - CSA Group
Year: 2010
Abstract: This Standard applies to rigid unplasticized poly (vinyl chloride)* boxes and fittings of the following types that are intended to be installed and used with rigid PVC conduit at a maximum working temperature of 75°C in accordance with the rules of the Canadian Electrical Code, Part I:
(a) junction boxes with an interior volume of 1640 mLt or less that are intended to provide access to wiring and to enclose splices and taps but not to support wiring devices;
(b) conduit boxes with an interior volume of 1640 mLt or less that are intended to be used as pull boxes but not to enclose splices and taps or support wiring devices;
(c) surface mounted device boxes with an interior volume of 1640 mLt or less that are intended primarily to support wiring devices but may also be used as a pull box or to enclose wiring joints;
(d) box covers of the blank and device types;
e) expansion joints that are intended to compensate for the linear expansion of a span of rigid PVC conduit;
(f) junction box terminal adapters that are intended to connect a length of PVC conduit by an elbow or other bend to a box;
(g) female adapters that are intended to connect a length of PVC conduit to a length of rigid metal conduit;
(h) reducers that are intended to connect lengths of two different sizes of rigid PVC conduit;
(i) caps that are intended to close the ends of unused lengths of rigid PVC conduit; and
(j) bell ends that are intended to provide a bushed opening at the open end of a length of rigid PVC conduit. *For convenience, the shorter term PVC is used in this Standard. tl640 mL is the volume of trade size known as 100 cubic inches.
(a) junction boxes with an interior volume of 1640 mLt or less that are intended to provide access to wiring and to enclose splices and taps but not to support wiring devices;
(b) conduit boxes with an interior volume of 1640 mLt or less that are intended to be used as pull boxes but not to enclose splices and taps or support wiring devices;
(c) surface mounted device boxes with an interior volume of 1640 mLt or less that are intended primarily to support wiring devices but may also be used as a pull box or to enclose wiring joints;
(d) box covers of the blank and device types;
e) expansion joints that are intended to compensate for the linear expansion of a span of rigid PVC conduit;
(f) junction box terminal adapters that are intended to connect a length of PVC conduit by an elbow or other bend to a box;
(g) female adapters that are intended to connect a length of PVC conduit to a length of rigid metal conduit;
(h) reducers that are intended to connect lengths of two different sizes of rigid PVC conduit;
(i) caps that are intended to close the ends of unused lengths of rigid PVC conduit; and
(j) bell ends that are intended to provide a bushed opening at the open end of a length of rigid PVC conduit. *For convenience, the shorter term PVC is used in this Standard. tl640 mL is the volume of trade size known as 100 cubic inches.
Collections
:
-
Statistics
CSA CAN/CSA-C22.2 NO. 85-M89
Show full item record
| contributor author | CSA - CSA Group | |
| date accessioned | 2017-09-04T15:14:03Z | |
| date available | 2017-09-04T15:14:03Z | |
| date copyright | 1989.09.01 (R 2010) | |
| date issued | 2010 | |
| identifier other | MCCBYEAAAAAAAAAA.pdf | |
| identifier uri | http://mapnamagz.yabesh.ir/std;query=authoF23793/handle/yse/12792 | |
| description abstract | This Standard applies to rigid unplasticized poly (vinyl chloride)* boxes and fittings of the following types that are intended to be installed and used with rigid PVC conduit at a maximum working temperature of 75°C in accordance with the rules of the Canadian Electrical Code, Part I: (a) junction boxes with an interior volume of 1640 mLt or less that are intended to provide access to wiring and to enclose splices and taps but not to support wiring devices; (b) conduit boxes with an interior volume of 1640 mLt or less that are intended to be used as pull boxes but not to enclose splices and taps or support wiring devices; (c) surface mounted device boxes with an interior volume of 1640 mLt or less that are intended primarily to support wiring devices but may also be used as a pull box or to enclose wiring joints; (d) box covers of the blank and device types; e) expansion joints that are intended to compensate for the linear expansion of a span of rigid PVC conduit; (f) junction box terminal adapters that are intended to connect a length of PVC conduit by an elbow or other bend to a box; (g) female adapters that are intended to connect a length of PVC conduit to a length of rigid metal conduit; (h) reducers that are intended to connect lengths of two different sizes of rigid PVC conduit; (i) caps that are intended to close the ends of unused lengths of rigid PVC conduit; and (j) bell ends that are intended to provide a bushed opening at the open end of a length of rigid PVC conduit. *For convenience, the shorter term PVC is used in this Standard. tl640 mL is the volume of trade size known as 100 cubic inches. | |
| language | English | |
| title | CSA CAN/CSA-C22.2 NO. 85-M89 | num |
| title | Rigid PVC Boxes and Fittings - Second Edition; General Instruction No. 1: September 1989; General Instruction No. 2: May 1990; Update No. 3: February 2006; Update No. 4: June 2011 and Update No. 5: January 2012 | en |
| type | standard | |
| page | 56 | |
| status | Active | |
| tree | CSA - CSA Group:;2010 | |
| contenttype | fulltext |