AASHTO T 281
Standard Method of Test for Vitrified Clay Pipe
Year: 2014
Abstract: These test methods cover the equipment for, and the techniques of, testing vitrified clay pipe prior to installation. Tests using whole pipe determine the resistance to crushing and hydrostatic forces. Tests using pipe fragments measure the amount of water absorption of the pipe body and the quantity of acid-soluble material that may be extracted from it.
The values stated in SI units are to be regarded as the standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Note 1—The following standards also apply to clay pipe and can be referenced for further information: ASTM C 12, C 425, C 700, and C 828.
The values stated in SI units are to be regarded as the standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Note 1—The following standards also apply to clay pipe and can be referenced for further information: ASTM C 12, C 425, C 700, and C 828.
Show full item record
| contributor author | AASHTO - American Association of State Highway and Transportation Officials | |
| date accessioned | 2017-09-04T18:34:35Z | |
| date available | 2017-09-04T18:34:35Z | |
| date copyright | 2014.01.01 | |
| date issued | 2014 | |
| identifier other | AJYLIFAAAAAAAAAA.pdf | |
| identifier uri | http://mapnamagz.yabesh.ir/std;query=autho4A5893/handle/yse/216761 | |
| description abstract | These test methods cover the equipment for, and the techniques of, testing vitrified clay pipe prior to installation. Tests using whole pipe determine the resistance to crushing and hydrostatic forces. Tests using pipe fragments measure the amount of water absorption of the pipe body and the quantity of acid-soluble material that may be extracted from it. The values stated in SI units are to be regarded as the standard. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note 1—The following standards also apply to clay pipe and can be referenced for further information: ASTM C 12, C 425, C 700, and C 828. | |
| language | English | |
| title | AASHTO T 281 | num |
| title | Standard Method of Test for Vitrified Clay Pipe | en |
| type | standard | |
| page | 8 | |
| status | Active | |
| tree | AASHTO - American Association of State Highway and Transportation Officials:;2014 | |
| contenttype | fulltext |