ASHRAE GUIDELINE 16

Selecting Outdoor, Return, and Relief Dampers for Air-Side Economizer Systems

Organization:
ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
Year: 2010

Abstract: This guideline covers the application of mixed air control dampers in air-handling units and systems that incorporate air-side economizer systems for cooling.
This guideline addresses the selection of control dampers based on damper characteristics and damper pressure drop.
This guideline is not intended to cover dampers used elsewhere in heating, ventilating, and air-conditioning (HVAC) systems.
This guideline does not cover air mixing.
PURPOSE
This guideline provides the basis for selecting and sizing control dampers (outdoor, return, and relief) commonly found in constant-air-volume (CAV) and variable-air-volume (VAV) air-handling units (AHU) and systems with air-side economizers.
URI: http://mapnamagz.yabesh.ir/std;query=autho4A5893/handle/yse/210154
Collections :
  • ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • Download PDF : (672.5Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    ASHRAE GUIDELINE 16

Show full item record

contributor authorASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
date accessioned2017-09-04T18:27:59Z
date available2017-09-04T18:27:59Z
date copyright01/23/2010
date issued2010
identifier otherIPKIRCAAAAAAAAAA.pdf
identifier urihttp://mapnamagz.yabesh.ir/std;query=autho4A5893/handle/yse/210154
description abstractThis guideline covers the application of mixed air control dampers in air-handling units and systems that incorporate air-side economizer systems for cooling.
This guideline addresses the selection of control dampers based on damper characteristics and damper pressure drop.
This guideline is not intended to cover dampers used elsewhere in heating, ventilating, and air-conditioning (HVAC) systems.
This guideline does not cover air mixing.
PURPOSE
This guideline provides the basis for selecting and sizing control dampers (outdoor, return, and relief) commonly found in constant-air-volume (CAV) and variable-air-volume (VAV) air-handling units (AHU) and systems with air-side economizers.
languageEnglish
titleASHRAE GUIDELINE 16num
titleSelecting Outdoor, Return, and Relief Dampers for Air-Side Economizer Systemsen
typestandard
page19
statusActive
treeASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.:;2010
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian