ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.: Recent submissions
Now showing items 641-660 of 2692
-
ASHRAE LV-11-C016
Abstract: ABSTRACT
Evaporative cooling systems have been used for millennia and represent an effective, low energy solution for many applications in dry climates. Recently, hybrid systems have been developed ... -
ASHRAE 90316
Abstract: Preface
There have been many interesting developments in the design of mechanical, plumbing, and electrical systems for earthquakes since publication of the first edition of this manual in 1999. ... -
ASHRAE GUIDELINE 24
Abstract: This guideline primarily applies to ventilation and IAQ for human occupancy in residential buildings three stories or fewer in height above grade, including manufactured and modular houses.
PURPOSE ... -
ASHRAE LO-09-018
Abstract: INTRODUCTION
Unless otherwise specified or discussed, the current references to air cooling and liquid cooling are directed to such implementations on the equipment design and not at the rack or room ... -
ASHRAE OR-16-C075
Abstract: The use of advanced engineering tools in HVAC industry has increased as the cost of computational fluid dynamics (CFD) has become more affordable for engineering firms. A thermal storage tank system utilized a series ... -
ASHRAE GUIDELINE 16
Abstract: This guideline covers the application of mixed air control dampers in air-handling units and systems that incorporate air-side economizer systems for cooling.
This guideline addresses the selection of control dampers ... -
ASHRAE LV-11-016
Abstract: ABSTRACT
Assessing and reducing vulnerability of building occupants to intentional indoor airborne releases of chemical and biological agents has acquired some importance in the past two decades. ... -
ASHRAE OR-10-045
Abstract: INTRODUCTION
Detailed building energy simulation tools such as DOE- 2 (LBL 1981) and EnergyPlus (Crawley et al. 2000) are commonly used to design sustainable buildings. These tools require hourly typical ... -
ASHRAE 17
Abstract: This standard is applicable to
(a) thermostatic expansion valves (also referred to in this standard as expansion valves) as defined in Section 3, "Definitions,"
(b) expansion valves of the direct-acting type but ... -
ASHRAE OR-16-C048
Abstract: This article deals with the use of the method proposed by POPPE on the thermodynamic analysis of evaporative water cooling towers of the countercurrent type. This method was developed in the 70s and is more precise in ...

درباره ما