MIL-I-3505C

INSULATION SHEET AND TAPE; ELECTRICAL, COIL AND SLOT, HIGH TEMPERATURE

Organization:
NAVY - SH - Naval Sea Systems Command (Ship Systems)
Year: 1960

Abstract: This specification covers high temperature mica-glass electrical insulation used in the coils and slots of rotating electrical machinery.
High temperature coil and slot electrical insulation shall be of the following classes, forms, and types, as specified (see 6.2):
                                             Class B   -With organic varnish     Class H   -With silicone varnish     Form S    -Sheet (See 3.5.1).     Form T    -Tape (See 3.5.2).     Type Mg.  -Pasted mica laminated with                   one layer of glass fiber in-                  sulation.     Type Pmg. -Pasted mica laminated with                  one layer of paper insula-                  tion on one side and one                  layer of glass fiber insula-                  tion on the other side. .                                                                                                                                Type Gmg. -Pasted mica sandwiched be-                  tween single layers of glass                  fiber insulation.


Intended Use: Class B material is used for generator, motor and transformer coils, slot liners and ground insulation, phase to phase insulation, phase and end insulation, primarily secondary separation, coil exteriors cable splices, coil and cell-wrapper tapes, and similar uses. The highest temperature (limiting "hottest spot" temperature) to which class B insulation may be subjected to continuously with normal life-expectancy is 130° C. Class H material is used for applications as specified in 6.1.1 and where the highest temperature (limiting "hottest spot" temperature) is 200° C. for normal life-expectancy.
URI: http://mapnamagz.yabesh.ir/std;query=autho1826AF67FCdardstandardsfen/handle/yse/174600
Collections :
  • NAVY - SH - Naval Sea Systems Command (Ship Systems)
  • Download PDF : (620.1Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    MIL-I-3505C

Show full item record

contributor authorNAVY - SH - Naval Sea Systems Command (Ship Systems)
date accessioned2017-09-04T17:51:21Z
date available2017-09-04T17:51:21Z
date copyright22202
date issued1960
identifier otherEZGIDAAAAAAAAAAA.pdf
identifier urihttp://mapnamagz.yabesh.ir/std;query=autho1826AF67FCdardstandardsfen/handle/yse/174600
description abstractThis specification covers high temperature mica-glass electrical insulation used in the coils and slots of rotating electrical machinery.
High temperature coil and slot electrical insulation shall be of the following classes, forms, and types, as specified (see 6.2):
                                             Class B   -With organic varnish     Class H   -With silicone varnish     Form S    -Sheet (See 3.5.1).     Form T    -Tape (See 3.5.2).     Type Mg.  -Pasted mica laminated with                   one layer of glass fiber in-                  sulation.     Type Pmg. -Pasted mica laminated with                  one layer of paper insula-                  tion on one side and one                  layer of glass fiber insula-                  tion on the other side. .                                                                                                                                Type Gmg. -Pasted mica sandwiched be-                  tween single layers of glass                  fiber insulation.


Intended Use: Class B material is used for generator, motor and transformer coils, slot liners and ground insulation, phase to phase insulation, phase and end insulation, primarily secondary separation, coil exteriors cable splices, coil and cell-wrapper tapes, and similar uses. The highest temperature (limiting "hottest spot" temperature) to which class B insulation may be subjected to continuously with normal life-expectancy is 130° C. Class H material is used for applications as specified in 6.1.1 and where the highest temperature (limiting "hottest spot" temperature) is 200° C. for normal life-expectancy.
languageEnglish
titleMIL-I-3505Cnum
titleINSULATION SHEET AND TAPE; ELECTRICAL, COIL AND SLOT, HIGH TEMPERATUREen
typestandard
page8
statusActive
treeNAVY - SH - Naval Sea Systems Command (Ship Systems):;1960
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian