Standard Specification for Masonry Cement

ASTM C91/C91M-25

Organization:
ASTM - ASTM International
Year: 2025

Abstract: This specification covers three types of masonry cement for use where mortar for masonry is required. Masonry cement shall conform to the applicable physical property requirements prescribed. The masonry cement shall be sampled in accordance with practice C 183. The temperature and relative humidity of the air in the vicinity of the mixing slab and dry materials, molds, base plates, and mixing bowl shall conform to the requirements of test method C 109/C 109M. Determine normal consistency by the Vicat apparatus in accordance with test method C 187. Determine autoclave expansion in accordance with test method C 151. Determine the time of setting by the Gillmore needle method in accordance with test method C 266. Determine the density of the masonry cement in accordance with test method C 188, using kerosene as the liquid. The sand shall be a blend of equal parts by weight of graded standard sand and standard 20-30 sand conforming to specification C 778. The compressive testing procedures for mortars are presented. Water retention shall be determined in accordance with the procedures in test method C 1506.
URI: http://mapnamagz.yabesh.ir/std;query=autho1826AF67FCDCAC4/handle/yse/343079
Collections :
  • ASTM - ASTM International
  • Download PDF : (289.1Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Standard Specification for Masonry Cement

Show full item record

contributor authorASTM - ASTM International
date accessioned2025-09-30T19:21:59Z
date available2025-09-30T19:21:59Z
date copyright2025
date issued2025
identifier otherc0091_c0091m-25.pdf
identifier urihttp://mapnamagz.yabesh.ir/std;query=autho1826AF67FCDCAC4/handle/yse/343079
description abstractThis specification covers three types of masonry cement for use where mortar for masonry is required. Masonry cement shall conform to the applicable physical property requirements prescribed. The masonry cement shall be sampled in accordance with practice C 183. The temperature and relative humidity of the air in the vicinity of the mixing slab and dry materials, molds, base plates, and mixing bowl shall conform to the requirements of test method C 109/C 109M. Determine normal consistency by the Vicat apparatus in accordance with test method C 187. Determine autoclave expansion in accordance with test method C 151. Determine the time of setting by the Gillmore needle method in accordance with test method C 266. Determine the density of the masonry cement in accordance with test method C 188, using kerosene as the liquid. The sand shall be a blend of equal parts by weight of graded standard sand and standard 20-30 sand conforming to specification C 778. The compressive testing procedures for mortars are presented. Water retention shall be determined in accordance with the procedures in test method C 1506.
languageEnglish
titleStandard Specification for Masonry Cementen
titleASTM C91/C91M-25num
typestandard
statusActive
treeASTM - ASTM International:;2025
contenttypefulltext
scope1.1 This specification covers three types of masonry cement for use where mortar for masonry is required. 1.2 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Values in SI units shall be obtained by measurement in SI units or by appropriate conversion, using the Rules for Conversion and Rounding given in Standard IEEE/ASTM SI 10, of measurements made in other units. Values are stated in only SI units when inch-pound units are not used in practice. 1.3 The text of this standard refers to notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.4 The following safety hazards caveat pertains only to Sections 15 and 16 of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.)2 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
identifier DOI10.1520/C0091_C0091M-25