IPC TM-650 2.4.33C
Flexural Fatigue and Ductility, Flat Cable
Organization:
IPC - Association Connecting Electronics Industries
Year: 1991
Abstract: With this test method, the flexural fatigue life for any given bend radius, the flexural fatigue behavior, and the ductility of the conductor metal in percent deformation after tensile failure can be determined.
Note: The indirect determination of foil ductility by using a fatigue test is made necessary by the geometry and dimensions of the foil samples, which make tensile elongation and rupture tests inadequate for ductility determination.
Note: The indirect determination of foil ductility by using a fatigue test is made necessary by the geometry and dimensions of the foil samples, which make tensile elongation and rupture tests inadequate for ductility determination.
Collections
:
-
Statistics
IPC TM-650 2.4.33C
Show full item record
| contributor author | IPC - Association Connecting Electronics Industries | |
| date accessioned | 2017-09-04T15:45:46Z | |
| date available | 2017-09-04T15:45:46Z | |
| date copyright | 03/01/1991 | |
| date issued | 1991 | |
| identifier other | PTCGCAAAAAAAAAAA.pdf | |
| identifier uri | http://mapnamagz.yabesh.ir/std;query=autho1826AF6708/handle/yse/48324 | |
| description abstract | With this test method, the flexural fatigue life for any given bend radius, the flexural fatigue behavior, and the ductility of the conductor metal in percent deformation after tensile failure can be determined. Note: The indirect determination of foil ductility by using a fatigue test is made necessary by the geometry and dimensions of the foil samples, which make tensile elongation and rupture tests inadequate for ductility determination. | |
| language | English | |
| title | IPC TM-650 2.4.33C | num |
| title | Flexural Fatigue and Ductility, Flat Cable | en |
| type | standard | |
| page | 3 | |
| status | Active | |
| tree | IPC - Association Connecting Electronics Industries:;1991 | |
| contenttype | fulltext |

درباره ما