PLUGS, DEHYDRATOR, INDICATING HUMIDITY

contributor authorNAVY - AS - Naval Air Systems Command
date accessioned2017-09-04T17:39:10Z
date available2017-09-04T17:39:10Z
date copyright01/31/1984
date issued1984
identifier otherDRTIDAAAAAAAAAAA.pdf
identifier urihttp://mapnamagz.yabesh.ir/std;query=authoF23793FDFCDCAC4/handle/yse/162087
description abstractThis specification establishes requirements for humidity indicating, dehydrator plugs that are intended to protect aircraft engine cylinders and other similar equipment against corrosion due to moisture and to indicate through color change unsafe levels of humidity (see 6.1).
Dehydrator plugs shall be of the following types, as specified (see 6.2).
        Type I - Reusable.          Type II - Reusable and refillable.


Unless otherwise specified, the following specifications and standards of the issue listed in that issue of the Department of Defense Index of Specification and Standards (DoDISS) specified in the solicitation form a part of this specification to the extent specified herein.
SPECIFICATIONS     Federal     PPP-B-601                   Boxes, Wood, Cleated-Plywood     PPP-B-621                   Boxes, Wood, Nailed and Lock Corner

Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Engineering Specifications and Standards Department (Code 93), Naval Air Engineering Center, Lakehurst, NJ 08733, by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter.
SPECIFICATIONS (Continued)     Federal (Continued)     PPP-B-636                   Box, Shipping, Fiberboard     PPP-C-96                    Cans, Metal, 28 Gage and Lighter     Military     MIL-D-3716                  Desiccants, Activated:  For Dynamic                                  Dehumidification     MIL-D-6054                  Drum, Metal; Shipping and Storage     MIL-R-6855                   Rubber, Synthetic, Sheets, Strips, Molded or                                  Extruded Shapes  STANDARDS     Federal     FED. TEST METHOD STD. NO. 101  Test Procedures for Packaging Materials     Military     MIL-STD-105                 Sampling Procedures and Tables for Inspection                                by Attributes     MIL-STD-129                 Marking, for Shipment and Storage     MIL-STD-130                 Identification Marking of U.S. Military                                Property     MS3396                      Plug, Dehydrator, Humidity Indicating, Engine                                Cylinder (14mm Thread)     MS3398                      Card-Humidity-Indicating Color Comparison     MS27215                     Plug, Dehydrator, Humidity Indicating, Engine                                Cylinder (18mm Thread)


(Copies of specifications, standards, handbooks, drawings and publications required by manufacturers in connection with specific acquisition functions should be obtained from the contracting activity or as directed by the contracting officer.)
In the event of conflict between the text in this specification and references cited herein, the text of the specification shall take precedence.
The following documents form a part of this specification to the extent specified herein. The issue of the document which is indicated as DOD adopted shall be the issue listed in the current DoDISS and the supplement thereto, if applicable.
        American Society For Testing And Materials (ASTM)             ASTM D 1748   -   Rust protection by metal preservation in the                              humidity cabinet.             ASTM D 3951   -   Standard practice for commercial packaging.


Applications for copies should be addressed to American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103.
Intended Use: The reusable plugs covered by this specification are intended for use in the preservation of reciprocating aircraft engines and related equipment. The type I plug is intended for use at field stations where facilities to reactivate the contained desiccant are available. The type II plug is intended for use when facilities to reactivate the contained desiccant are not available, or where it would be more convenient to refill the deactivated plug with fresh activated desiccant. The type II plug may be reactivated, if desired. Plugs are satisfactory for use when the total moisture content of the contained desiccant does not exceed 7.5 percent at the time the plug is placed in use.