ASME PTC 12.3
Performance Test Code on Deaerators
| contributor author | ASME - ASME International | |
| date accessioned | 2017-09-04T17:27:14Z | |
| date available | 2017-09-04T17:27:14Z | |
| date copyright | 1997.10.31 (R 2004)(R 2009) | |
| date issued | 2009 | |
| identifier other | CMMPFBAAAAAAAAAA.pdf | |
| identifier uri | http://mapnamagz.yabesh.ir/std;query=authoF23793FD08/handle/yse/150393 | |
| description abstract | This Code applies to deaerating heaters and deaerators equipped with either shell-and-tube or direct contact, vent-condensing sections. The Code describes the test method and procedures for the determination of dissolved oxygen in water for deaerating equipment at concentrations up to 75 µg/L (ppb). This Code also describes the method for determining the terminal temperature difference (TTD). Other methods of dissolved oxygen measurement are included in Appendices A, B and C. These may be used as an adjunct to the Code. | |
| language | English | |
| title | ASME PTC 12.3 | num |
| title | Performance Test Code on Deaerators | en |
| type | standard | |
| page | 55 | |
| status | Active | |
| tree | ASME - ASME International:;2009 | |
| contenttype | fulltext |