Show simple item record

Standard Method of Test for Flash Point with Tag Open-Cup Apparatus for Use with Material Having a Flash Point Less Than 93°C (200°F)

contributor authorAASHTO - American Association of State Highway and Transportation Officials
date accessioned2017-09-04T18:50:07Z
date available2017-09-04T18:50:07Z
date copyright01/01/2012
date issued2012
identifier otherKTRXXEAAAAAAAAAA.pdf
identifier urihttp://mapnamagz.yabesh.ir/std;query=autho4A5893/handle/yse/231464
description abstractThis method covers the procedure for the determination of flash points by the tag open-cup apparatus of cutback asphalts having flash points of less than 93°C (200°F).
The sample is placed in the tester and heated at a slow and constant rate. A small test flame is passed at a uniform rate in a level plane across the cup at specified intervals. The flash point is the lowest temperature at which application of the test flame causes the vapor at the surface of the liquid to flash.
Note 1 - Specifications commonly designate the Cleveland Open-Cup method (T 48) for asphalt binders and cutback asphalts having flash points above 79.5°C (175°F).
The values stated in SI units are to be regarded as the standard.
This test may involve hazardous materials, operations, and equipment. This test does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
languageEnglish
titleAASHTO T 79num
titleStandard Method of Test for Flash Point with Tag Open-Cup Apparatus for Use with Material Having a Flash Point Less Than 93°C (200°F)en
typestandard
page6
statusActive
treeAASHTO - American Association of State Highway and Transportation Officials:;2012
contenttypefulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record