<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns="http://www.w3.org/2005/Atom">
<title>Defence Standards</title>
<link href="https://yse.yabesh.ir/std/handle/yse/1" rel="alternate"/>
<subtitle/>
<id>https://yse.yabesh.ir/std/handle/yse/1</id>
<updated>2026-07-16T19:37:57Z</updated>
<dc:date>2026-07-16T19:37:57Z</dc:date>
<entry>
<title>SMD-5962-90705</title>
<link href="https://yse.yabesh.ir/std/handle/yse/232346" rel="alternate"/>
<author>
<name>DLA - CC - DLA Land and Maritime</name>
</author>
<id>https://yse.yabesh.ir/std/handle/yse/232346</id>
<updated>2017-09-04T18:50:56Z</updated>
<published>1991-01-01T00:00:00Z</published>
<summary type="text">SMD-5962-90705; MICROCIRCUITS, DIGITAL, HIGH SPEED CMOS, BCD DECADE COUNTER, ASYNCHRONOUS RESET, MONOLITHIC SILICON
DLA - CC - DLA Land and Maritime
This drawing forms a part of a one part - one part number documentation system (see &lt;a&gt;6.6&lt;/a&gt; herein).  Two product assurance classes consisting of military high reliability (device classes B, Q, and M) and space application (device classes S and V), and a choice of case outlines and lead finishes are available and are reflected in the Part or Identifying Number (PIN).  Device class M microcircuits represent non-JAN class B microcircuits in accordance with &lt;a&gt;1.2.1&lt;/a&gt; of MIL-STD-883, "Provisions for the use of MIL-STD-883 in conjunction with compliant non-JAN devices".  When available, a choice of radiation hardness assurance (RHA) levels are reflected in the PIN.   &lt;br&gt;The PIN shall be as shown in the following example:    &lt;a&gt;&lt;img alt="CHART" /&gt;&lt;/a&gt;  &lt;br&gt;Device classes M, B, and S RHA marked devices shall meet the MIL-M-38510 specified RHA levels and shall be marked with the appropriate RHA designator.  Device classes Q and V RHA marked devices shall meet the MIL-I-38535 specified RHA levels and shall be marked with the appropriate RHA designator.  A dash (-) indicates a non-RHA device.  &lt;br&gt;The device type(s) shall identify the circuit function as follows:  &lt;/span&gt;&lt;pre&gt;       &lt;u&gt;Device type&lt;/u&gt;          &lt;u&gt;Generic number&lt;/u&gt;                        &lt;u&gt;Circuit function&lt;/u&gt;             01                  54HCT160     BCD decade counter, asynchronous reset, TTL compatible inputs&lt;/pre&gt; &lt;br&gt;  &lt;br&gt;The device class designator shall be a single letter identifying the product assurance level as follows:  &lt;pre&gt;       &lt;u&gt;Device class&lt;/u&gt;                  &lt;u&gt;Device requirements documentation&lt;/u&gt;              M                        Vendor self-certification to the requirements for non-JAN class B                                      microcircuits in accordance with &lt;a&gt;1.2.1&lt;/a&gt; of MIL-STD-883            B or S                     Certification and qualification to MIL-M-38510            Q or V                     Certification and qualification to MIL-I-38535&lt;/pre&gt; &lt;br&gt;  &lt;br&gt;For device classes M, B, and S, case outline(s) shall meet the requirements in appendix C of MIL-M-38510 and as listed below.  For device classes Q and V, case outline(s) shall meet the requirements of MIL-I-38535, appendix C of MIL-M-38510, and as listed below.  &lt;pre&gt;       &lt;u&gt;Outline letter&lt;/u&gt;                            &lt;u&gt;Case outline&lt;/u&gt;                E       D-2 (16-lead, .840" &amp;#215; .310" &amp;#215; .200"), dual-in-line package&lt;/pre&gt; &lt;br&gt;  &lt;br&gt;The lead finish shall be as specified in MIL-M-38510 for classes M, B, and S or MIL-I-38535 for classes Q and V.  Finish letter "X" shall not be marked on the microcircuit or its packaging.  The "X" designation is for use in specifications when lead finishes A, B, and C are considered acceptable and interchangeable without preference.  &lt;br&gt;  &lt;pre&gt;  Supply voltage range (V&lt;sub&gt;CC&lt;/sub&gt;)  - - - - - - - - - - - - - - -    &amp;#8722;0.5 V dc to +7.0 V dc   DC input voltage  - - - - - - - - - - - - - - - - - - - -    &amp;#8722;0.5 V dc to V&lt;sub&gt;CC&lt;/sub&gt; + 0.5 V dc   DC output voltage - - - - - - - - - - - - - - - - - - - -    &amp;#8722;0.5 V dc to V&lt;sub&gt;CC&lt;/sub&gt; + 0.5 V dc   Clamp diode current - - - - - - - - - - - - - - - - - - -    &amp;#177;20 mA   DC output current (per pin) - - - - - - - - - - - - - - -    &amp;#177;25 mA   DC V&lt;sub&gt;CC&lt;/sub&gt; or GND current (per pin) - - - - - - - - - - - - -    &amp;#177;50 mA   Storage temperature range - - - - - - - - - - - - - - - -    &amp;#8722;65&amp;#176;C to +150&amp;#176;C   Maximum power dissipation (P&lt;sub&gt;D&lt;/sub&gt;)  - - - - - - - - - - - - -    500 mW  &lt;a&gt;&lt;u&gt;2&lt;/u&gt;/&lt;/a&gt;   Lead temperature (soldering, 10 seconds)  - - - - - - - -    +300&amp;#176;C   Thermal resistance, junction-to-case (&amp;#952;&lt;sub&gt;JC&lt;/sub&gt;)- - - - - - - -    See MIL-M-38510, appendix C   Junction temperature (T&lt;sub&gt;J&lt;/sub&gt;) - - - - - - - - - - - - - - - -    +175&amp;#176;C&lt;/pre&gt; &lt;br&gt;  &lt;br&gt;  &lt;pre&gt;  Supply voltage (V&lt;sub&gt;CC&lt;/sub&gt;)  - - - - - - - - - - - - - - - -    +4.5 V dc to +5.5 V dc   Input voltage (V&lt;sub&gt;IN&lt;/sub&gt;)   - - - - - - - - - - - - - - - -    0.0 V dc to V&lt;sub&gt;CC&lt;/sub&gt;   Output voltage (V&lt;sub&gt;OUT&lt;/sub&gt;) - - - - - - - - - - - - - - - -    0.0 V dc to V&lt;sub&gt;CC&lt;/sub&gt;   Case operating temperature (T&lt;sub&gt;C&lt;/sub&gt;) - - - - - - - - - - -    &amp;#8722;55&amp;#176;C to +125&amp;#176;C   Input rise and fall time (t&lt;sub&gt;r&lt;/sub&gt;, t&lt;sub&gt;f&lt;/sub&gt;):     V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V, 5.5 V    - - - - - - - - - - - - - - -    0 to 500 ns   Minimum setup time, Pn to CP (t&lt;sub&gt;s1&lt;/sub&gt;):     T&lt;sub&gt;C&lt;/sub&gt; = +25&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - - - - - - -    10 ns     T&lt;sub&gt;C&lt;/sub&gt; = &amp;#8722;55&amp;#176;C to +125&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - -    15 ns   Minimum setup time, PE to CP, TE to CP (t&lt;sub&gt;s2&lt;/sub&gt;):     T&lt;sub&gt;C&lt;/sub&gt; = +25&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - - - - - - -    13 ns     T&lt;sub&gt;C&lt;/sub&gt; = &amp;#8722;55&amp;#176;C to +125&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - -    20 ns   Minimum setup time, [S bar][P bar][E bar] to CP (t&lt;sub&gt;s3&lt;/sub&gt;):     T&lt;sub&gt;C&lt;/sub&gt; = +25&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - - - - - - -    12 ns     T&lt;sub&gt;C&lt;/sub&gt; = &amp;#8722;55&amp;#176;C to +125&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - -    18 ns   Minimum pulse width, CP (t&lt;sub&gt;w1&lt;/sub&gt;):     T&lt;sub&gt;C&lt;/sub&gt; = +25&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - - - - - - -    16 ns     T&lt;sub&gt;C&lt;/sub&gt; = &amp;#8722;55&amp;#176;C to +125&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - -    24 ns   Minimum pulse width, [M bar][R bar] (t&lt;sub&gt;w2&lt;/sub&gt;):     T&lt;sub&gt;C&lt;/sub&gt; = +25&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - - - - - - -    20 ns     T&lt;sub&gt;C&lt;/sub&gt; = &amp;#8722;55&amp;#176;C to +125&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - -    30 ns   Minimum hold time, Pn to CP (t&lt;sub&gt;h1&lt;/sub&gt;):     T&lt;sub&gt;C&lt;/sub&gt; = +25&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - - - - - - -    5 ns     T&lt;sub&gt;C&lt;/sub&gt; = &amp;#8722;55&amp;#176;C to +125&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - -    5 ns   Minimum hold time, TE to CP, PE to CP(t&lt;sub&gt;h2&lt;/sub&gt;):     T&lt;sub&gt;C&lt;/sub&gt; = +25&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - - - - - - -    3 ns     T&lt;sub&gt;C&lt;/sub&gt; = &amp;#8722;55&amp;#176;C to +125&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - -    3 ns   Minimum hold time, [S bar][P bar][E bar] to CP (t&lt;sub&gt;h3&lt;/sub&gt;):     T&lt;sub&gt;C&lt;/sub&gt; = +25&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - - - - - - -    3 ns     T&lt;sub&gt;C&lt;/sub&gt; = &amp;#8722;55&amp;#176;C to +125&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - -    3 ns   Minimum recovery time, [M bar][R bar] to CP (t&lt;sub&gt;REC&lt;/sub&gt;):     T&lt;sub&gt;C&lt;/sub&gt; = +25&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - - - - - - -    15 ns     T&lt;sub&gt;C&lt;/sub&gt; = &amp;#8722;55&amp;#176;C to +125&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - -    22 ns   Maximum clock frequency, CP (f&lt;sub&gt;MAX&lt;/sub&gt;):     T&lt;sub&gt;C&lt;/sub&gt; = +25&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - - - - - - -    30 MHz     T&lt;sub&gt;C&lt;/sub&gt; = &amp;#8722;55&amp;#176;C to +125&amp;#176;C, V&lt;sub&gt;CC&lt;/sub&gt; = 4.5 V - - - - - - - - -    20 MHz&lt;/pre&gt; &lt;br&gt;  &lt;br&gt;  &lt;pre&gt;  Fault coverage measurement of manufacturing     logic tests (MIL-STD-883, test method 5012) - - - - -   XX percent  &lt;a&gt;&lt;u&gt;3&lt;/u&gt;/&lt;/a&gt;&lt;/pre&gt; &lt;br&gt;  &lt;br&gt;&lt;b&gt;&lt;u&gt;Intended Use:&lt;/u&gt;&lt;/b&gt; Microcircuits conforming to this drawing are intended for use for Government microcircuit applications (original equipment), design applications, and logistics purposes.  Microcircuits covered by this drawing will replace the same generic device covered by a contractor-prepared specification or drawing.  Device classes B and Q devices will replace device class M devices.  &lt;br&gt;
</summary>
<dc:date>1991-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>A-A-59775 VALID NOTICE 1</title>
<link href="https://yse.yabesh.ir/std/handle/yse/232322" rel="alternate"/>
<author>
<name>DLA - CC - DLA Land and Maritime</name>
</author>
<id>https://yse.yabesh.ir/std/handle/yse/232322</id>
<updated>2017-09-04T18:50:55Z</updated>
<published>2012-01-01T00:00:00Z</published>
<summary type="text">A-A-59775 VALID NOTICE 1; Oil Pan, Drip
DLA - CC - DLA Land and Maritime
</summary>
<dc:date>2012-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>DODD 1030.2 06/04/04</title>
<link href="https://yse.yabesh.ir/std/handle/yse/232330" rel="alternate"/>
<author>
<name>DODD - DoD Directives Service</name>
</author>
<id>https://yse.yabesh.ir/std/handle/yse/232330</id>
<updated>2017-09-04T18:50:55Z</updated>
<published>2004-01-01T00:00:00Z</published>
<summary type="text">DODD 1030.2 06/04/04; VICTIM AND WITNESS ASSISTANCE PROCEDURES
DODD - DoD Directives Service
REISSUANCE AND PURPOSE. This Instruction:  &lt;br&gt;Reissues reference (a) to implement policy, assign responsibilities, and prescribe procedures under reference (b) to assist victims and witnesses of crimes committed in violation of reference (c).  &lt;br&gt;Implements reference (d), sections &lt;a&gt;1512-1514&lt;/a&gt; of title 18, United States Code, DoD 5400.7-R, and sections &lt;a&gt;113&lt;/a&gt; (note), 1058, 1059 and 1408 of title 10, United States Code (reference (e) through (g)) by providing guidance on assisting victims and witnesses of crime from initial contact through investigation, prosecution and confinement.  &lt;br&gt;Establishes annual reporting requirements on assistance provided to victims and witnesses of crime.  &lt;br&gt;APPLICABILITY. This Instruction applies to the Office of the Secretary of Defense, the Military Departments, the Chairman of the Joint Chiefs of Staff, the Combatant Commands, the Office of the Inspector General of the Department of Defense, the Defense Agencies, the DoD Field Activities, and all other organizational entities in the Department of Defense (hereafter referred to collectively as the "DoD Components"). The term "Military Services," as used herein, refers to the Army, the Navy, the Air Force, and the Marine Corps.
</summary>
<dc:date>2004-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>A-A-51689</title>
<link href="https://yse.yabesh.ir/std/handle/yse/232318" rel="alternate"/>
<author>
<name>DOD - MB - Defense Health Agency, Medical Logistics Division</name>
</author>
<id>https://yse.yabesh.ir/std/handle/yse/232318</id>
<updated>2017-09-04T18:50:55Z</updated>
<published>1986-01-01T00:00:00Z</published>
<summary type="text">A-A-51689; DISK, MICROMETER, MICROSCOPE EYEPIECE
DOD - MB - Defense Health Agency, Medical Logistics Division
</summary>
<dc:date>1986-01-01T00:00:00Z</dc:date>
</entry>
</feed>
